Technology

Hands‑free subcutaneous injection, engineered mechanically.

Our device concepts are applied to the skin, activated once, and then complete the injection automatically — from needle insertion to retraction.

01The principle

Activation is the last thing the user has to do.

With a conventional handheld injector, the user positions, presses and holds the device until delivery is finished. Our concepts move that work into the device: it adheres to the skin and runs the injection sequence itself.

  • Skin-adhered device design
  • Automatic injection sequence after a single activation
  • Needle insertion and retraction handled by the mechanism
  • Feedback when the injection is complete
Schematic cross-section of the device principle during injection: the mechanical drive pushes the plunger and the needle is inserted into the subcutaneous tissueSkinSubcutaneous tissueActivation buttonCompletion indicatorMechanical driveDrug containerNeedleAdhesive pad
Schematic concept illustration · not to scale
02Technology areas

What the technology brings together.

Six areas define the platform across both device concepts.

Skin-adhered device design

The device attaches at the injection site and stays in position during delivery.

Automatic injection mechanism

Insertion, delivery and retraction run as one sequence.

Hands‑free after activation

No holding, pressing or repositioning while the dose is delivered.

Device usability

Designed to keep user interaction simple and clear.

Mechanical engineering

Injection sequences driven by mechanical mechanisms.

Drug-delivery development

Developed with pharmaceutical integration and primary containers in mind.

03Technical features

Technical overview.

A structured view of the technology. Quantitative specifications are published once verified.

Mechanical actuation

The injection sequence is driven mechanically.

Automatic needle insertion

After activation, the mechanism inserts the needle into the subcutaneous tissue without further action from the user.

Needle retraction

At the end of delivery, the needle is withdrawn back into the device housing before the device is removed.

Injection feedback

The device indicates when the injection is complete, so the user knows when it can be removed.

Device configuration

How the mechanism, drug container and user interface are arranged within the skin-adhered housing.

Primary packaging compatibility

Designed with standard pharmaceutical primary packaging in mind, to ease integration with existing drug products. Compatibility is assessed for each drug product.

Cartridge and plunger interface

How the mechanism drives the plunger of the drug container is central to the design and to partner integration work.

Device usability

User steps are kept few and clear. Final usability will be established through formal usability engineering.

Engineering approach

Concepts move from principle to mechanism design, prototypes and feasibility work, with the user interaction defined in parallel.

04Specifications

Platform specifications.

A design-level summary. Quantitative figures — volume, duration, needle and dimensions — are published once verified; we do not publish estimated or target values.

Platform-level specifications (both device concepts)
ParameterSpecification
ActuationMechanical
Delivery routeSubcutaneous
Device formSkin-adhered (autoinjector and wearable bolus injector)
OperationAutomatic after a single activation
NeedleAutomatic insertion and retraction
FeedbackCompletion indication
Regulatory statusNone claimed; not commercially available

Device-specific parameters are listed on each device page.

Evaluating a subcutaneous therapy?

Talk to us about integrating your drug product with the hands-free platform.